Audco Ball Valves

Full Bore Ball Valves

AB44 - Standard series

This 3-piece Ball Valve is the most easily on-line maintainable in its class. By removing three body connector bolts and loosening the fourth, the body can be swung away using the fourth bolt as the fulcrum, to carry out any installation or maintenance operation on the valve, thus reducing downtime. This valve can be offered in a wide variety of body and seat combinations.

AFB44 - Fire-safe series

This 3-piece fire-safe design Ball Valve features a secondary metal seat which renders the valve firesafe. When the seat is totally sublimated in a fire, the ball moves and rests against the lip, forming a metalto- metal seat, thus ensuring leak-tightness

Specifications Pressure Testing Test pressures
Max. cold working pressure 69kg/cm2 for screwed/socketweld
end valves with PTFE
seat
103kg/cm2 for screwed/socketweld
end valves with polyfill
seat
As per flange rating for flanged
valves
Ends kg/cm2 (psi)  
  Shell Scr./Socket weld (air)
Flanged 150 (hydrostatic)
Flanged 300 (hydrostatic)
Flanged 600 (hydrostatic)
5.6
31.5
79.0
154.0
(80)
(450)
(1125)
(2225)
   
Valve design BS 5159 for A44 Series
BS 5351 for AF44 Series
Seat All valves (air) 5.6 (80)
         
Fire Test (for AFB44)
Testing
API 607 4th edition
Testing API 598 for flanged valves
NOTE Pressure testing as per BS 6755 available on
special request.
Shell hydrostatic test can be done for screwed
and socket-weld end valves on special request.
Shell hydrostatic test can be done as per Class
800 rating for both versions on special request.
 
Face-to-face dimensions ASME B16.10 for flanged
valves and AIL Standard for
screwed/socket-weld end
 
   
   
Full Bore Ball Valves Single-piece / Two-piece design

F15 Fire-safe Series (Class 150) F30

Fire-safe Series (Class 300)

These high performance full bore ball valves come in single-piece design (in sizes of 15 - 40mm) as well as in two-piece design (in sizes of 50 - 200mm). Advanced features such as fire safety, antistatic capability, cavity relief and blow-out proof stem are built into these valves. They are supplied with an integral actuator mounting flange with drilled and tapped holes conforming to ISO 5211.

Specifications   Pressure Testing Test pressures  
Valve design BS 5351     Ends kg/cm2 (psi)
    Shell Class 150 (hydrostatic)
Class 300 (hydrostatic)
31.5
79.0
(450)
(1125)
   
Fire test API 607, 4th edition  
  Seat Class 150 (air)
Class 300 (air)
5.6
5.6
(80)
(80)
Pressure testing API 598 (testing as per
BS 6755 Part I on special
request)
   
   
Face-to-face dimensions ASME B16.10
(compliance to BS 2080 can
be offered on request)
   
       
End flange dimensions ASME B16.5 Class 150 RF
and Class 300 RF